pc mobile

Performance test such as stress/transmittance

Determination of o-benzene 4P by ROHS 2.0 liquid chromatograph

Determination of o-benzene 4P by ROHS 2.0 liquid chromatograph
Product
description

Product description

Features

The high-performance QC-10Tvp gradient high performance liquid chromatograph measures the four phthalic substances regulated by the European Union in the sample, namely: dibutyl benzyl phthalate (BBP) and phthalic acid Diisobutyl ester (DIBP), dibutyl phthalate (DBP), di(2-ethyl)hexyl phthalate (DEHP).


1. Introduction of high performance liquid chromatograph system:


The new version of QC-10T liquid chromatograph is composed of QC-10Tvp infusion pump, SPD-10Tvp UV variable wavelength detector, manual injection valve, chromatographic column and chromatographic data workstation. It is recommended to use Survey software for the chromatographic data workstation. It uses a digital communication system, an ultra-wide dynamic range, and can counter-control the liquid chromatography on a computer. It can be widely used in many analysis fields such as environmental protection, medicine, food, chemical industry, environment, etc. The new version of high performance liquid chromatograph complies with GLP/GMP, FDA, 21CFR Part11 specification requirements.


2. Parameter index of high performance liquid chromatograph system:

QC-10Tvp high pressure constant flow infusion pump:

Pump tightness

Micro volume series double plunger

Micro volume series double plunger

Flow setting range

0.001~9.999ml/min (Adjust the flow rate in 0.001ml/min steps)

Maximum infusion pressure

6000psi

Flow setting range

≤0.5%


Flow stability error

≤0.2%RSD

Pressure pulsation

±1% (0-100%, 2-liquid gradient of water/acetone aqueous solution

Less than 0.1MPa, flow rate 1mL/min, pressure drop less than 5MP

Time program function

Have


size

W260*H130*D420mm



SPD-10Tvp UV-visible variable wavelength detector:

Wavelength repeatability errorStatic noiseStatic baseline driftMinimum detection concentrationFlow cell volume

Infusion method


190nm~700nm

Wavelength indication error

≤±1nm

≤±0.1nm

Dynamic noise

≤±0.75×10-5AU(甲醇,1mL/min,254nm,20℃


≤±0.5×10-5AUEmpty cell, response time 1 second, 20°C

Dynamic baseline drift

≤±1×10-4AU/h(甲醇,1mL/min,254nm,20℃


≤0.5×10-4AU/hEmpty cell, response time 1 second, 20°C

Linear range

104


4×10-9g/mL (naphthalene/methanol solution)

Qualitative repeatability

RSD ≤0.1% 6


Quantitative repeatability

RSD ≤0.5% 6

Spectral bandwidth

6nm

10μL

Optical path

10mm


时Inter-program function

Have

size

W260*H130*D420mm

 

3. Configuration sheet for determination of o-benzene 4P by high performance liquid chromatograph:

 

ROHS2.0 control list of 4 o-benzene experiment instruments (BBP, DIBP, DBP, DEHP)

name

Specification configuration

Quantity

Remarks

High performance liquid chromatography gradient system

image.png

2 QC-10Tvp high pressure infusion pumps


1 SPD-10Tvp ultraviolet visible light detector


QC-10Tvp solvent tray 1


1 set of 8725i manual injection valve


QC-10Tvp gradient high pressure static mixer 1 set


1 set of survey chromatographic data processing system


Chromatography injection needle 1


1 set of binary high-pressure gradient start-up kit


1 dedicated column


1 set



Chromatographic pretreatment equipment

Chromatographic pretreatment equipment

image.png

1 ultrasonic cleaner


1 oil-free vacuum pump


Volume filter 1 set


Organic microporous filter 2 packs


Organic microporous membrane 2 boxes


1 chromatographic column thermostat


1 set



Sample processing equipment

Sample processing equipment

image.png

1 electronic balance


2 pipettes


2 packs of pipette tips


1 grinder


2 screens


1 set of computer


1 printer


1 set



Reagents and standards

Reagents and standards

image.pngimage.png

4 bottles of acetonitrile (4L)


1 bottle of methanol (4L)


1 box of ultrapure water


1 set of phthalate standard products


1 set



Glassware

Glassware

20 glass beakers       50 brown volumetric flasks 2 mobile phase bottles

4 glass measuring cylinders  1 enamel tray

1 pair of scissors       1 pair of tweezers

1 medicine spoon           1 box of qualitative filter paper

1 box of weighing paper        2 boxes of medical latex gloves

1 flat-bottomed ground flask       Latex tube 2.5 meters                          image.png

1套


PS1:

The customer-provided test bench, water source, power supply, and at least 7 three-hole sockets

PS2:

It is recommended that at least two personnel receive training and operation, if necessary, video can be recorded


1. The process of determining o-benzene 4P by high performance liquid chromatograph:

image.pngimage.pngSample test process

1. Choose an appropriate amount of representative samples


2. Crush the sample into particles


3. Weigh 1.0g accurately


4. Place in a 50mL volumetric flask


5. Add 40mL acetonitrile


6. Ultrasound 70min


7. Let stand and cool to room temperature


8. Add acetonitrile to the volume and shake well

9、image.png0.22umOrganic membrane filtration

10. Computer analysis and determination

11. Calculation results

Instrument and software operation
process

1. Turn on the power of the instrument, turn on the column thermostat and computer


2. Open the chromatography software (Survey) and enter the collection interface


3. Software and instrument communication connection


4. Load the 4P instrument configuration method (established when the instrument is debugged)


5. Load the sampling sequence (established when the instrument is debugged)


6. Wait until the baseline is stable


7、image.pngimage.pngInjection (20uL): sample injection

8. Collect spectrum: sample chromatogram


9. Calculation results (load the standard curve and establish it when the instrument is debugged)


10. Print report


11. System cleaning and maintenance (training will be conducted when the instrument is debugged)

image.png

2. Consumables involved in the determination of o-benzene 4P by HPLC

耗材清单

Model name

Specifications

Quantity

备注

Deuterium lamp

Hamatsu, Japan

1-Only


Chographic column

Hamatsu, Japan

 1 Root


Pump sealing ring

C18,250mm*4.6mm*5um.

1-Only


Organic microhole filter

Φ13 × 0.22 (100 pcs / pack)

1-Only


Organic micropore filter membrane

 

Φ50 × 0.22 (50 tablets / box)

 1. Package


Liquid shift gun gun head

10ul

 1. Package


Liquid shift gun

gun head

10ml

 1. Package


Acetonitrile

Chromatography is pure 4L

1 bottle


Methanol

Chromatography is pure 4L

1 bottle


Ultra-pure water

Can be replaced by Wahaha or Yibao, if the Watsons

1. Box


Phthalate Standard Products

BBP、DIBP、DBP、DEHP

Each bottle


 启诚详情.jpg