X-ray fluorescence spectrometer
Model number: QCEDX800
Functions: ROHS analysis, heavy metal component analysis, halogen analysis, coating analysis
Instrument product introduction
1. Application areas
QCEDX800 is an economical, practical and easy-to-operate X-ray fluorescence spectrometer; (RoHS analysis, halogen analysis, heavy metal component analysis, metal coating analysis) for lead (Pb), mercury (Hg), cadmium (Cd), chromium (Cr) ), bromine (Br), chlorine (Cl)) arsenic (As), selenium (Se), antimony (Sb) and other elements have a good detection limit and accuracy. Comprehensive application of FP method, neural network method, experience coefficient method, basic parameter method analysis software. It can fully meet the relevant control requirements of RoHS/WEEE/EN71/ELV directive. The well-designed open working curve function is especially suitable for multi-material factory process control.
Applicable to: ROHS analysis of incoming materials such as hardware, connectors, electronics, electrical, connectors, electroplating, PCB, plastics, leather, shoe materials, etc.
2. Product features (test objects: powder, solid, liquid)
1. Fast element analysis from sulfur (S) to uranium (U);
2. The detection sensitivity is 0.01% to 100%;
3. The measurement time is short, each measurement only takes 50-300 seconds
4. The 5 million pixel color CCD system is used for sample image observation.
5. There are a variety of collimators and filters to choose from. The combination of 6 groups of collimators and 4 groups of filters can be automatically switched to meet the application of various substance testing methods.
6. The latest American electric refrigeration Si-Pin detector can improve the stability of measurement and the accuracy of analysis without consumables.
7. The appearance is streamlined design, the mechanical structure is simple and reliable.
8. International leading qualitative and quantitative analysis algorithms: FP basic algorithm, empirical coefficient method, neural network method, basic parameter method;
9. The design of fully enclosed metal chassis and leak-proof protection switch can better protect the personal safety of the operator. Streamlined appearance, beautiful and generous, the internal space of the instrument is large, the sample cavity is large, the internal ventilation of the instrument is excellent, and the electromagnetic interference is effectively shielded
10. Leading ultra-short optical path design, air-cooled X-ray tube supporting unique light tube control program, better heat dissipation, good heat dissipation system, can ensure the long use of the instrument, and can effectively extend the X-ray Tube life
11. Top-illuminated type: It can meet the testing needs of samples of various shapes, and the accurate sample imaging collimation system can realize accurate point measurement of samples.
12. Automatic spectral line identification, simultaneous qualitative and quantitative analysis of multiple elements, allowing users to easily understand the composition of the analyzed sample, and an automatic safety protection switch is set to ensure the safe use of users.
输入电压:AC 220V±5% | ||
Test pair image | Powder, solid, liquid | |
Sample thickness | Not limited; the strict requirements are as follows: The thickness of the light alloy (such as aluminum alloy, magnesium alloy, etc.) detection unit should be at least 5mm, the thickness of other alloy detection units should be at least 1mm, the thickness of liquid detection units should be at least 15mm, and the thickness of other materials detection units should be 3~5mm. between. | |
Sample test area | 0- ø25MM Optional | |
Analysis and detection limit | 1PPM | |
Analysis content | PPM-99.99% | |
| Measurement deviation of 1000PPM, measurement accuracy deviation of ± 50PPm, 5%100PPM measurement accuracy deviation is ± 10PPm, 5% -10% relative to homogeneous sample of Cr,Hg,Pb,Br,Cd ≤ 2PPM | |
High voltage generator: | ||
Input voltage | 24VDC±10% | |
The output voltage | 0-50kV | |
Output current | 0-1.0mA | |
Output accuracy | 0.01% | |
X-ray tube: | ||
X-ray tube target material | W targets, Rh, Mo, Ag, Cr targets are optional | |
X-ray tube target material | Be window | |
Electrical parameters | 50W,4-50kV,0-1.0mA | |
Cold confirmation method | 50W,4-50kV,0-1.0mA | |
Service life | Over 15,000 hours | |
Detector: | ||
Detection range | Sulfur (S) -Uranium (U) | |
Resolution | 139 ± 5eV | |
Detection window | Beryllium window, window area: 25mm2 | |
Spectrum Processing System | ||
Processor Type | Processor Type | |
Spectrum channel number | 2048 Channel | |
2048 Channel | 2048 Channel | |
Optical path system and sample observation: | ||
Collimator system | 5 Collimators, min. 0.5mm | |
Light Filter | 4 Filters | |
Sample observation system | 500 Vientiane Plain HD CCD Camera | |
Appearance of the instrument and sample room size | ||
Appearance of the instrument and sample room size | (Long × Width × High): 600 mm × 460 mm × 380mm | |
Maximum size of sample cavity test sample | 460 mm ×300 mm×120mm | |
460 mm × 300 mm × 120mm | ≤20kg | |
Sample console control mode | Fixed sample table | |
Minimum detection limit of the element | Cd/Cr/Hg/Br≤2ppm,Pb≤2ppm Cl≤15ppm | |
Computer and software | ||
Control the computer | Lenovo Brand Machine 2G Memory 500G hard disk capacity | |
Display device | Lenovo 19 " LCD monitor | |
Operating system | win7 ENChinese | |
Report the Results | Excel format | |
Software | ROHS analysis, halogen analysis; (optional coating thickness analysis software, metal component analysis software) | |
Software Type | FP basic parameter method, empirical coefficient method, neural network method, and basic parameter method. | |
Software Language | Simplified Chinese, English, and Other | |
Spectrum display | Peak characterization, KLM labeling, spectral overlap comparison | |
Weight and dimensions: | ||
600 (W) x460 (D) x380 (H) mm About 45kg s | 600(W)x460(D)x380 (H)mm | |
Weight and dimensions: | About 45kg s | |
Use environment: | ||
Working environment | Temperature: 10-28 degrees, humidity: 40% -80%RH | |
Power supply system | Single phase 220V ± 10%, operating voltage within allowable range | |
Other | 1. is not close to producing strong magnetic field, electric field, high frequency, etc 2. Reduce the vibration 3. Less dust, low humidity, and no corrosive gas 4. No direct sunlight |
Four, software function:
The software can video observe the placement of the sample.
Dozens of elements can be analyzed at the same time, the analysis time is as short as 50-300 seconds, and the qualitative analysis can be automatically performed, and the report is accurate.
The instrument can be automatically initialized and calibrated; it has a variety of spectral fitting analysis methods
RoSH analysis software
1Function introduction: Detect the five elements Cd, Pb, Hg, Br, Cr, Cl involved in the six substances in the EU RoHS directive
² The professionally designed software for RoHS testing is more targeted.
² Simple operation interface, easy to use, no need for professional operation
² The Chinese and English interface is automatically switched, and with the third-party language editing function to test different samples, the collimator can be automatically switched by the software setting
² Convenient report output method, which can be imported into EXCEL form; and there is a non-editable independent report output format
² The calibration of the instrument is convenient and simple
² The measurement results can be displayed in real time, which is convenient for customers to shorten the measurement time.
² It can also perform rough material judgment function on samples.
Detecting and analyzing spectrum pattern:
注: (本图片样式只供参考,不代表真实测试结果)
Note: (This picture style is for reference only and does not represent the real test result)
Thickness analysis software
1Function introduction: detect and analyze the thickness and composition of the coating
² Can analyze single coating, multiple coatings and alloy coatings
² Analysis methods with a variety of coatings
² Can display English and metric units at the same time
4.2.2 Spectral pattern of detection and analysis:
Note: (This picture style is for reference only and does not represent the real test result)
Detection Analysis Spectrum for Thickness:
Note: (This picture style is for reference only and does not represent the real test result)
Full element analysis software
1 Function introduction: It can accurately and quickly detect and analyze the composition of the product.
² There are a variety of mathematical models for analysis and calculation, which is convenient for the analysis and measurement of different materials and different samples. Multiple working curves can be made. Each curve has independent test conditions and sample testing is convenient.
² The tube pressure and tube flow of the instrument can be set freely, and the measurement of the elements contained in the sample is more targeted
² With automatic qualitative analysis function to facilitate the analysis of materials
² With virtual spectrum comparison function, convenient for material comparison and analysis