pc mobile

Environmental testing

UL1581 vertical + horizontal combustion test chamber

UL1581 vertical + horizontal combustion test chamber
Product
description

Product description

Features

This combustion testing machine is designed and manufactured strictly in accordance with the UL1581 standard. It is mainly used to test the fire protection of insulation or coverings.


product manual


This machine is widely used in the fields of wire and cable, connector, electronics, communication, electric power, mechanical engineering, metallurgy, etc.


This combustion test is designed and manufactured strictly in accordance with the UL1581 standard. It is mainly used to test the fire protection of insulation or coverings. The tester has the advantages of high accuracy, automatic timing, automatic end of the test, horizontal and vertical combustion integration. This testing machine has an exhaust system that can be automatically opened and closed, a large-area observation window, a lighting device, a flame calibration system, a blowtorch automatic positioning system, etc. In addition, the testing machine adopts PLC+touch screen control, the panel is centralized, and the operation is simple and convenient. This instrument complies with the requirements of VW-1, FT-1, FT-2 in the LU1581, ASTMD5025, ASTMD5207 standards


Technical Parameters


1. Standard: Comply with UL1581 standard


2. Power supply: AC220V, 50Hz, 3A.


3. Specification size: 1700×1400×2550mm (length×width×height).


4. Internal effective volume: >4.0m3.


5. Volume above the flame: 2 m3.


6. Blowtorch American original Bunsen burner specifications:


Inner diameter: 9.5±0.3mm.


Flame nozzle diameter: 0.90±0.03mm.


The length of the vent: 1.60±0.05mm.


7. Blow torch angle: 90 degrees, inclined 20 degrees (optional, determined according to the combustion method).


8. Combustion gas: Methane (provided by the customer, purity above 98%).


9. Fixtures: 3 groups (arranged according to different combustion methods).


10. Ignition method: high-voltage automatic ignition, touch screen button or manual control box button operation.


11. The number of times of fire: 0~999 (can be set), accuracy: ±1 word.


12. Fire time: 0~999.9S can be set arbitrarily, the standard requires 15S, precision: 0.1S.


13. Stop fire time: 0~999.9S can be set arbitrarily, the standard requires 15S, accuracy: 0.1S.


14. Wire continuous burning time: 0~999.9S displayed on the touch screen, controlled by the button of the hand control box, accuracy: 0.1S.


15. Flame calibration time: the time required for the temperature to rise from 100℃ to 700℃±3℃: 54s±2s or 84s±2s.


16. Flow meter range: 0~1L/min, accuracy: 2%.


17. The accuracy of the thermostat (inside the instrument): ±1℃. Touch screen display accuracy: 0.1℃.


18. Flame height: 125mm (inclined burning at 20 degrees) and 50mm (burning at 90 degrees) can be adjusted.


19. Flame removal method: automatic inclination.


The temperature range of thermocouple: 0℃~1300℃.


20. Using touch screen, PLC and stepping motor control.


21. U-shaped pressure tube, flow meter, and flame nozzle adopt imported components.

启诚详情.jpg